VACUUM VACUUM DISTILLATION VACUUM DRYERS VACUUM EJECTORS VACUUM ELECTRIC FURNACES VACUUM PUMP VAN DER WAALS EQUATION VAN DER WAALS EQUATION OF STATE VAN DER WAALS FORCES VAN DER WAALS ISOTHERMS VAN DRIEST'S DAMPING FORMULA VAN DRIEST'S EXPRESSION FOR TURBULENT VISCOSITY VAN DRIEST'S MIXING LENGTH MODEL VAN LAAR EQUATION VAN'T HOFF EQUATION VAN'T HOFF ISOTHERM VANADIUM VANE ANEMOMETERS VAPOR ABSORPTION CYCLE VAPOR BUBBLE, EQUILIBRIUM OF VAPOR EXPLOSIONS VAPOR PRESSURE VAPOR PRESSURE THERMOMETER VAPOR PRESSURE, EQUILIBRIUM, CHANGE WITH TEMPERATURE VAPOR SHEAR STRESS EFFECTS VAPOR SHEAR, EFFECT ON CONDENSATION VAPOR SORPTION REFRIGERATION CYCLE VAPOR-COMPRESSION REFRIGERATION CYCLE VAPOR-LIQUID EQUILIBRIUM VAPOR-LIQUID SEPARATION VAPORIZATION VARIABLE AREA FLOWMETER VARIABLE FLUID PROPERTIES Variable refractive index media VARIABLE VISCOSITY EFFECTS VARIATION OF FLUID PROPERTIES VDI VECTORS VEHICLES INTERSECTION VELOCITY BOUNDARY LAYER VELOCITY DEFECT Velocity Head VELOCITY MEASUREMENT VELOCITY OF LIGHT VELOCITY OF SOUND VELOCITY OF SOUND IN TWO-PHASE MIXTURES VELOCITY RATIO VELOCITY, AVERAGE PHASE VELOCITY, SUPERFICIAL VENA CONTRACTA VENTILATION VENTURI EJECTORS VENTURI METERS VENTURI NOZZLE VENTURI SCRUBBER VENTURI TUBES VEREIN DEUTSCHEUR INGENIEUR, VDI VERTICAL SHAFT KILNS VERTICAL THERMOSYPHON REBOILER VIBRATION VIBRATION IN HEAT EXCHANGERS VIBRATION, FLOW INDUCED Vibro-rotational transitions VIENNA CONVENTION VIEWFACTOR VINYL CHLORIDE MONOMER VIRIAL COEFFICIENT VIRIAL EXPANSION VIRTUAL MACHINE VIRTUAL MEMORY VISCOELASTIC FLUIDS VISCOELASTIC SOLIDS VISCOMETER VISCOPLASTIC BEHAVIOR OF METAL POWDERS VISCOSITY VISCOSITY MEASUREMENT VISCOSITY OF AIR VISCOSITY OF BUBBLY MIXTURES VISCOSITY OF GASES VISCOUS DISSIPATION RATE VISCOUS DISSIPATIVE FLUID VISCOUS FINGERING MECHANISMS VISIBILITY VISIBLE LIGHT VISUALIZATION OF DRYOUT PHENOMENON VISUALIZATION OF FLOW VISUALIZATION OF STREAMLINES VISUALIZING VORTEX FORMATION Void fraction VOID FRACTION DISTRIBUTION PATTERN Void fraction measurement VOID WAVE PROPAGATION VOIDS VOLATIZATION VOLTERRA INTEGRAL EQUATIONS VOLUME FILLING VOLUME FORCES VOLUME MEAN DIAMETER, VMD VON KARMAN CONSTANT VON KARMAN STREET VON KARMAN VELOCITY DISTRIBUTION VON KARMAN VORTEX STREET VON KARMAN, THEODORE (1881-1963) VORTEX VORTEX BREAKDOWN VORTEX CHAMBER VORTEX EFFECTS VORTEX EXCITATION OF TUBES VORTEX FLOWMETERS VORTEX GENERATORS VORTEX INSTABILITY VORTEX MIXER VORTEX SEPARATORS Vortex Shedding VORTEX STREET VORTEX VIBRATIONS VORTICAL FLOWS Vortices Vorticity VORTICITY TRANSPORT EQUATION VULCANISTATION
W X Y Z

VENTURI METERS

Interlinking between Articles
Visual Navigation

Venturi meters are flow measurement instruments which use a converging section of pipe to give an increase in the flow velocity and a corresponding pressure drop from which the flowrate can be deduced. They have been in common use for many years, especially in the water supply industry.

The classical Venturi meter, whose use is described in ISO 5167-1: 1991, has the form shown in Figure 1

Classical Vetituri meter design. (From B. S. 7405 (1991) Fig. 3.1.4, with permission of B.S.I.)

Figure 1. Classical Vetituri meter design. (From B. S. 7405 (1991) Fig. 3.1.4, with permission of B.S.I.)

For incompressible flow if the Bernoulli Equation is applied between two planes of the tappings,

(1)

where p, ρ and ū are the pressure, density and mean velocity and the subscripts 1 and 2 refer to the upstream and downstream (throat) tapping planes.

From continuity

(2)

where is the volumetric flowrate and D and d the pipe and throat diameters.

Combining Eqs. (1) and (2)

(3)

where β is the diameter ratio, d/D. In reality, there is a small loss of total pressure, and the equation is multiplied by the discharge coefficient, C, to take this into account:

(4)

where Δp is the differential pressure (≡p1 − p2). The discharge coefficient of a Venturi meter is typically 0.985, but may be even higher if the convergent section is machined. Discharge coefficients for uncalibrated Venturi meters, together with corresponding uncertainties, are given in ISO 5167-1: 1991.

If the fluid being metered is compressible, there will be a change in density when the pressure changes from p1 to p2 on passing through the contraction. As the pressure changes quickly, it is assumed that no heat transfer occurs and because no work is done by or on the fluid, the expansion is isentropic. The expansion is almost entirely longitudinal and an expansibility factor, ε, can be calculated assuming one-dimensional flow of an ideal gas:

(5)

where τ is the pressure ratio, p2/p1, and κ the isentropic exponent. The expansibility factor is applied to the flow equation in the same way as the discharge coefficient.

Various forms of construction of a Venturi meter are employed, depending on size, but all are considerably more expensive than the orifice plate. However, because most of the differential pressure is recovered by means of the divergent outlet section, the Venturi causes less overall pressure loss in a system and thus saves energy: the overall pressure loss is generally between 5 and 20 per cent of the measured differential pressure. The Venturi meter has an advantage over the orifice plate in that it does not have a sharp edge which can become rounded; however, the Venturi meter is more susceptible to errors due to burrs or deposits round the downstream (throat) tapping.

The lengths of straight pipe required upstream and downstream of a Venturi meter for accurate flow measurement are given in ISO 5167-1: 1991. These are shorter than those required for an orifice plate by a factor which can be as large as 9. However, Kochen et al. show that the minimum straight lengths between a single upstream 90° bend and a Venturi meter in the Standard are too short by a factor of about 3.

REFERENCES

British Standards Institution (1991) Guide to selection and application of flowmeters for the measurement of fluid flow in closed conduits, BS 7405.

International Organization for Standardization, Measurement of fluid flow by means of pressure differential devices—Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full. ISO 5167-1: 1991.

Kochen, G., Smith, D. J. M., and Umbach, A. (1989) Installation effects on Venturi tube flowmeters, Intech Engineers Notebook, October 1989,41-43.

References

  1. British Standards Institution (1991) Guide to selection and application of flowmeters for the measurement of fluid flow in closed conduits, BS 7405.
  2. International Organization for Standardization, Measurement of fluid flow by means of pressure differential devices—Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full. ISO 5167-1: 1991.
  3. Kochen, G., Smith, D. J. M., and Umbach, A. (1989) Installation effects on Venturi tube flowmeters, Intech Engineers Notebook, October 1989,41-43.